VTS Group is a leading producer in the ventilation and air conditioning trade.

We are carefully watching the market and react quickly to its changes. That enables us to provide our clients with the best solutions perfectly tailored to their needs. Climatic zones and latitudes do not matter to us. Our air handling units guarantee air comfort regardless of a particular facility's location. We are real specialists in good climate.

Description of buildings

In plot the production & warehouse building and gatehouse are placed.  

Photo No. 1 The production & warehouse building with gatehouse, front side

Photo No. 2 The production & warehouse building, back and front side

Photo No. 3 The production & warehouse building, inside

Photo No. 4 Gatehouse, external view

Description:

  • Modern production, logistic  & warehouse with self-supporting, steel frame construction
  • Dimensions: width 70 m x length 31,9 m  x height 11,9 m (in ridge). The plot allows to contruct additional 50m lenght
  • Building area            2.233 m2
  • Usable area              2.160 m2
  • Building capacity        20.010 m3
  • Constructed in: 1988
  • Foundations
    • on the front side, cast in-situ reinforced-concrete foundation footings support the columns of the building and the retaining wall (which also serves as a ground-set foundation to support the external walls).
    • Ground-set composite walls consist of a 25 cm thick concrete wall separated from a light-weight wet-applied plaster layer by 5cm of polystyrene.
  • Building frame
    • Cold-formed I-beam posts and frames to which panels are attached that are made from bilaterally zink-electroplated roofing sheets covered with silicone polyester paint on their external side
    • Cold-formed purlins made from Z sections
    • Wall and roof braces and wall girts made from cold-formed steel sections
  • External walls
    • Layered sheet /8 cm thick fibre glass/ sheet steel
  • Flat roof
    • Roofing sheet, 12 cm thick fibre-glass mat, purlin-mounted
    • Mounted polycarbonate skylights
    • Electrically-operated smoke release/ventilation vents
  • Floor topping
    • Allowable load on the floor topping:
      • 5 tonnes of uniformly distributed load per 1 m2
      • 4 tonnes per shelving leg
  • Slab on grade, on a 20cm thick sand and 15 cm thick crushed stone base
  • A 16 cm thick B-30 concrete slab reinforced twice with a reinforcing mesh (on the top and bottom)
  • Floor surface hardened with Korodur and trowelled mechanically
  • Finishing works
    • Base course from clinker tiles
    • Finishings from aluminium sections, anodised along the bottom edge of the walls
    • Steel gutters, zinc electroplated and coated; down spouts square-shaped
    • Gutters with gradients in the direction of down spouts
    • Carpentry and metal work – typical, industrial
    • Electrically-powered Hormann brand entrance door.
  • Instalations
    • Heating and ventilation network of hall (gas)
    • Water and sewage network
    • Storm drainage system fitted with petrol, oil, and mud separators for parking areas, roads and other passage/traffic facilities